{"id":5819,"date":"2024-08-02T14:15:31","date_gmt":"2024-08-02T12:15:31","guid":{"rendered":"https:\/\/www.primalucelab.it\/blog\/?post_type=ht_kb&#038;p=5819"},"modified":"2024-09-18T09:47:14","modified_gmt":"2024-09-18T07:47:14","slug":"play-how-to-use-sequencer-to-start-an-image-sequence-acquisition","status":"publish","type":"ht_kb","link":"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/","title":{"rendered":"PLAY, how to use SEQUENCER to start an image sequence acquisition"},"content":{"rendered":"<p style=\"text-align: justify;\">In this article you can read how to use SEQUENCER to start an image sequence acquisition. Once you\u2019re happy with the acquisition settings and the object framing, you can press the large PLAY button in the lower-right part of PLAY window and you will see a new popup window that will show you the Sequencer.<\/p>\n<p style=\"text-align: justify;\"><!--more--><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5857\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1000\" height=\"537\" srcset=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png 1920w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-300x161.png 300w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-1024x550.png 1024w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-768x412.png 768w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-50x27.png 50w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-1536x825.png 1536w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-60x32.png 60w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-100x54.png 100w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Here you can select, for every image set corresponding to a line in the table, a different:<\/p>\n<ul>\n<li>Type: light, dark, bias, flat-auto, flat-manual<\/li>\n<li>Filter: this is enabled if you connected also a motorised filter wheel<\/li>\n<li>Expo (s): this is the exposure time in seconds for each capture<\/li>\n<li>Binning: this is the binning settings for your captures<\/li>\n<li>Shots: this is the number of pictures you want to capture for every line of the Sequencer<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">If you want to add a line, you can press the \u201cAdd line\u201d button. You can delete any line by pressing the trash icon and activate every line by clicking on the Enable field corresponding to every line.<\/p>\n<p>Just below the Sequencer table, you can find the sequence acquisition options:<\/p>\n<ul>\n<li>\u201c<strong>Automatic shutdown procedure<\/strong>\u201d automatically closes caps (if connected), close dome (if connected), park telescope, disconnect devices from PLAY and turn off the EAGLE (if PLAY is installed on an EAGLE computer)<\/li>\n<li>\u201d<strong>Autostacking<\/strong>\u201d option to activate Autostacking processing<\/li>\n<li>\u201c<strong>Close Cover at the end of the capture<\/strong>\u201d that is visible if you connect to PLAY also an ALTO telescope cover motor. If selected, it automatically closes the telescope cap at the end of the sequence acquisition.<\/li>\n<li>\u201c<strong>Close Dome at the end of the capture<\/strong>\u201d that is visible if you connect to PLAY also a dome. If selected, it automatically closes the dome at the end of the sequence acquisition.<\/li>\n<li>\u201c<strong>Use motorised cap for DARK and BIAS capture<\/strong>\u201d that is visible if you connect to PLAY also an ALTO telescope cover motor. If selected, it automatically closes the telescope cap before acquisition of a DARK or BIAS acquisition (if you activate it, please make sure the environment is completely dark &#8211; no environment lights around the telescope &#8211; otherwise your calibration images won\u2019t be really dark and they won\u2019t be useful for image processing calibration).<\/li>\n<li>\u201c<strong>Auto park mount after sequence ends<\/strong>\u201d that is visible if you connect to PLAY also a mount. If selected, it automatically parks the mount at the end of the sequence acquisition.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">When you completed your settings, press the \u201cLAUNCH YOUR CAPTURE\u201d button to start acquisition of all the images. During sequence acquisition, in the bottom-left part of the screen you can read acquisition settings data like remaining time, exposure time and binning of images, number of images completed aver the total requested.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5820\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-2.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1001\" height=\"539\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">Since PLAY allows you to automate capture of different type of images (light, darks, bias and flats), the Sequencer will capture images based on the devices you use with your telescope (for example it can record a flat image only if you connect to PLAY a GIOTTO flat field generator and it can automatically close the cap only if you connect to PLAY a ALTO cover motor) and based on the capture settings.<\/p>\n<p style=\"text-align: justify;\">In particular, if you connect to PLAY GIOTTO flat field generator in the Sequencer you can choose to record one or more flat images and you have 2 options: FLAT-MANUAL and FLAT-AUTO. If you select FLAT-MANUAL, the Sequencer will let you type in your preferred GIOTTO brightness and camera exposure time that it will use to record your FLAT images.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5840\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-3.png\" alt=\"\" width=\"1003\" height=\"94\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">If you select FLAT-AUTO, PLAY will launch the automatic calculation of best exposure time and flat panel settings, then it will record your flat images with your settings.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5820\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-4.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1001\" height=\"539\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">If you also connect an ALTO telescope cover motor, the Sequencer will automatically control motorised cap status during your pictures acquisitions. If your cap is closed when you start your Sequence acquisition, PLAY will open the cap. If you enable a FLAT-AUTO or FLAT-MANUAL acquisition, ALTO will automatically close the cap in order to move GIOTTO in front of your telescope. If you select the option \u201cUse motorised cap for DARK and BIAS capture\u201d under Configurator -&gt; Cover motor, ALTO will automatically close the cap when the Sequencer will start acquisition of DARK and BIAS images.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5820\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-5.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1001\" height=\"539\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">PLEASE NOTE: If you want to record DARK (especially) and BIAS files by closing the cap with ALTO, you need to make sure you\u2019re collecting these images in a very dark environment (for example not affected by strong light pollution) since a motorised cap can\u2019t \u201cseal\u201d the telescope optics and prevent any external light to enter the telescope. If external light enter telescope when you record DARK (especially since these may have very long exposure time) and BIAS images, these calibration files won\u2019t be good to use in your calibration process (since no very \u201cdark\u201d anymore). If you\u2019re not sure about this, please deselect \u201cUse motorised cap for DARK and BIAS capture\u201d under Configurator -&gt; Cover motor: in this case PLAY, before starting DARK and BIAS images capture, will ask you to manually put the telescope cap in front of your telescope.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5820\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-6.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1001\" height=\"539\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">If you have the GIOTTO flat field generator but you have no ALTO cover motor connected to PLAY, before the Sequencer starts recording FLAT images, it will remind you to have the GIOTTO is fixed in front of telescope instead of its cap. When you will press &#8220;Next&#8221; button, PLAY will continue by recording FLAT images in the way (auto or manual) you selected. At the end of the FLAT images capture, you can remove GIOTTO from the telescope.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5820\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-7.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1001\" height=\"539\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">If you have the ALTO cover motor but no GIOTTO connected to PLAY (for example if you attached a cap to ALTO just to remotely open or close your telescope) you can\u2019t select FLAT-MANUAL or FLAT-AUTO but you can use ALTO to automatically close the cap before the Sequencer will start capturing DARK or BIAS images if you selected the \u201cUse motorized cap for DARK and BIAS capture\u201d option under Configurator -&gt; Cover Motor.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5820\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-8.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1001\" height=\"539\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">If you don\u2019t connect to PLAY GIOTTO flat field generator and ALTO cover motor, PLAY won\u2019t allow you to record FLAT images and, before starting to capture BIAS or DARK images, it will remind you to cover telescope with its cap.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5820\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-9.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1001\" height=\"539\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">When a Sequence is running, if you want to stop the sequence you can press the large STOP button in the in the lower-right part of PLAY window and you will see a new popup window that asks for confirmation. Press the OK button to stop sequence acquisition. Please note that, based on the time of your sequence acquisition, you will need to wait until the end of the actual picture before the sequence will be stopped.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5820\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-10.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1001\" height=\"539\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">When the sequence will be completed, you will see a popup window confirming the capture of all the images. If you click the \u201cClick here to open FITS directory\u201d button, PLAY will open the directory where you will find all your pictures in FITS format, as set in he camera configurator. Default directory is:<\/p>\n<p style=\"text-align: center;\">C:\/Users\/(user name)\/Pictures\/PLAY<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5820\" src=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-11.png\" alt=\"PLAY, how to use SEQUENCER to start an image sequence acquisition\" width=\"1001\" height=\"539\" \/><\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">FITS is the format commonly used in astrophotography in order to have the maximum image quality and allow the best flexibility in astrophotography processing. Now you can use a dedicated astrophotography software in order to process your images sequence and get your final picture.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In this article you can read how to use SEQUENCER to start an image sequence acquisition. Once you\u2019re happy with the acquisition settings and the object framing, you can press the large PLAY button in the lower-right part of PLAY window and you will see a new popup window that&#8230;<\/p>\n","protected":false},"author":2,"featured_media":5857,"template":"","format":"standard","meta":{"footnotes":""},"ht-kb-category":[75],"ht-kb-tag":[],"class_list":["post-5819","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-play"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>PLAY, how to use SEQUENCER to start an image sequence acquisition - PrimaLuceLab<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PLAY, how to use SEQUENCER to start an image sequence acquisition - PrimaLuceLab\" \/>\n<meta property=\"og:description\" content=\"In this article you can read how to use SEQUENCER to start an image sequence acquisition. Once you\u2019re happy with the acquisition settings and the object framing, you can press the large PLAY button in the lower-right part of PLAY window and you will see a new popup window that...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/\" \/>\n<meta property=\"og:site_name\" content=\"PrimaLuceLab\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-18T07:47:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1031\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.primalucelab.it\/blog\/#organization\",\"name\":\"PrimaluceLab\",\"url\":\"https:\/\/www.primalucelab.it\/blog\/\",\"sameAs\":[],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.primalucelab.it\/blog\/#logo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/03\/logo.png\",\"contentUrl\":\"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/03\/logo.png\",\"width\":300,\"height\":83,\"caption\":\"PrimaluceLab\"},\"image\":{\"@id\":\"https:\/\/www.primalucelab.it\/blog\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.primalucelab.it\/blog\/#website\",\"url\":\"https:\/\/www.primalucelab.it\/blog\/\",\"name\":\"PrimaLuceLab\",\"description\":\"Aim high\",\"publisher\":{\"@id\":\"https:\/\/www.primalucelab.it\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.primalucelab.it\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png\",\"contentUrl\":\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png\",\"width\":1920,\"height\":1031,\"caption\":\"PLAY, how to use SEQUENCER to start an image sequence acquisition\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#webpage\",\"url\":\"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/\",\"name\":\"PLAY, how to use SEQUENCER to start an image sequence acquisition - PrimaLuceLab\",\"isPartOf\":{\"@id\":\"https:\/\/www.primalucelab.it\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#primaryimage\"},\"datePublished\":\"2024-08-02T12:15:31+00:00\",\"dateModified\":\"2024-09-18T07:47:14+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.primalucelab.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\/\/www.primalucelab.it\/blog\/support\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PLAY, how to use SEQUENCER to start an image sequence acquisition\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PLAY, how to use SEQUENCER to start an image sequence acquisition - PrimaLuceLab","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/","og_locale":"en_US","og_type":"article","og_title":"PLAY, how to use SEQUENCER to start an image sequence acquisition - PrimaLuceLab","og_description":"In this article you can read how to use SEQUENCER to start an image sequence acquisition. Once you\u2019re happy with the acquisition settings and the object framing, you can press the large PLAY button in the lower-right part of PLAY window and you will see a new popup window that...","og_url":"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/","og_site_name":"PrimaLuceLab","article_modified_time":"2024-09-18T07:47:14+00:00","og_image":[{"width":1920,"height":1031,"filesize":785179,"url":"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png","path":"\/var\/www\/vhosts\/primalucelab.com\/primalucelab.com\/public_html\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png","size":"full","id":5857,"alt":"PLAY, how to use SEQUENCER to start an image sequence acquisition","pixels":1979520,"type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/www.primalucelab.it\/blog\/#organization","name":"PrimaluceLab","url":"https:\/\/www.primalucelab.it\/blog\/","sameAs":[],"logo":{"@type":"ImageObject","@id":"https:\/\/www.primalucelab.it\/blog\/#logo","inLanguage":"en-US","url":"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/03\/logo.png","contentUrl":"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/03\/logo.png","width":300,"height":83,"caption":"PrimaluceLab"},"image":{"@id":"https:\/\/www.primalucelab.it\/blog\/#logo"}},{"@type":"WebSite","@id":"https:\/\/www.primalucelab.it\/blog\/#website","url":"https:\/\/www.primalucelab.it\/blog\/","name":"PrimaLuceLab","description":"Aim high","publisher":{"@id":"https:\/\/www.primalucelab.it\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.primalucelab.it\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"ImageObject","@id":"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#primaryimage","inLanguage":"en-US","url":"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png","contentUrl":"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png","width":1920,"height":1031,"caption":"PLAY, how to use SEQUENCER to start an image sequence acquisition"},{"@type":"WebPage","@id":"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#webpage","url":"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/","name":"PLAY, how to use SEQUENCER to start an image sequence acquisition - PrimaLuceLab","isPartOf":{"@id":"https:\/\/www.primalucelab.it\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#primaryimage"},"datePublished":"2024-08-02T12:15:31+00:00","dateModified":"2024-09-18T07:47:14+00:00","breadcrumb":{"@id":"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.primalucelab.com\/blog\/support\/play-how-to-use-sequencer-to-start-an-image-sequence-acquisition\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.primalucelab.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/www.primalucelab.it\/blog\/support\/"},{"@type":"ListItem","position":3,"name":"PLAY, how to use SEQUENCER to start an image sequence acquisition"}]}]}},"uagb_featured_image_src":{"full":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png",1920,1031,false],"thumbnail":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-150x150.png",150,150,true],"medium":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-300x161.png",300,161,true],"medium_large":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-768x412.png",643,345,true],"large":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-1024x550.png",643,345,true],"ht-kb-thumb":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-50x27.png",50,27,true],"1536x1536":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-1536x825.png",1536,825,true],"2048x2048":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1.png",1920,1031,false],"ultp_layout_landscape_large":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-1200x800.png",1200,800,true],"ultp_layout_landscape":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-870x570.png",870,570,true],"ultp_layout_portrait":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-600x900.png",600,900,true],"ultp_layout_square":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-600x600.png",600,600,true],"post-thumbnail":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-60x32.png",60,32,true],"hkb-thumb":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-100x54.png",100,54,true],"crp_thumbnail":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2024\/09\/PLAY-1-9-3-how-to-use-SEQUENCER-to-start-an-image-sequence-acquisition-1-150x150.png",150,150,true]},"uagb_author_info":{"display_name":"Filippo Bradaschia","author_link":"https:\/\/www.primalucelab.com\/blog\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"In this article you can read how to use SEQUENCER to start an image sequence acquisition. Once you\u2019re happy with the acquisition settings and the object framing, you can press the large PLAY button in the lower-right part of PLAY window and you will see a new popup window that...","_links":{"self":[{"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb\/5819","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"version-history":[{"count":5,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb\/5819\/revisions"}],"predecessor-version":[{"id":5882,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb\/5819\/revisions\/5882"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/media\/5857"}],"wp:attachment":[{"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/media?parent=5819"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb-category?post=5819"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb-tag?post=5819"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}