{"id":3184,"date":"2020-09-17T17:29:03","date_gmt":"2020-09-17T15:29:03","guid":{"rendered":"https:\/\/www.primalucelab.it\/blog\/?post_type=ht_kb&#038;p=3184"},"modified":"2022-01-31T14:01:38","modified_gmt":"2022-01-31T13:01:38","slug":"first-use-use-ecco2-eagle-manager-primo-utilizzo","status":"publish","type":"ht_kb","link":"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/","title":{"rendered":"First use: use ECCO2 with EAGLE Manager"},"content":{"rendered":"<p style=\"text-align: justify;\">ECCO2 is designed to work with the EAGLE (compatible with EAGLE4, EAGLE LE, EAGLE3 and EAGLE2 &#8211; in order to work with EAGLE2\u00a0it requires update of OS and EAGLE Manager to v3) and, in order to automatically control dew heater power it doesn&#8217;t need any external software. In order to use the ECCO2 with EAGLE, please follow these steps:<\/p>\n<p style=\"text-align: justify;\">1) <em>Connect temperature sensors to the ECCO2:<\/em> temperature sensor ports in the ECCO2 are numbered in the same order as the dew heater ports on the EAGLE. Connect temperature sensor to the ECCO2 port number corresponding to the port number on the EAGLE where you connected the dew heater. For example, if your telescope dew heater is connected to port 5 of your EAGLE, connect the temperature sensor to the port 5 of the ECCO2. Please do not connect the other side (the probe) to your telescope since, before start using the ECCO2, temperature probes will have to be calibrated. Please have the temperature probes free and not connected to different objects: for example you can leave them on the table or hanging freely.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3171\" src=\"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-1.jpg\" alt=\"\" width=\"1000\" height=\"600\" srcset=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-1.jpg 1000w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-1-300x180.jpg 300w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-1-768x461.jpg 768w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-1-50x30.jpg 50w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-1-60x36.jpg 60w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-1-100x60.jpg 100w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<p style=\"text-align: justify;\">2) <em>Click on the ECCO button in the EAGLE Manager interface<\/em> and, after a few seconds, ECCO2 will activate.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3173\" src=\"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-2.jpg\" alt=\"\" width=\"1000\" height=\"600\" srcset=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-2.jpg 1000w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-2-300x180.jpg 300w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-2-768x461.jpg 768w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-2-50x30.jpg 50w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-2-60x36.jpg 60w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-2-100x60.jpg 100w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<p style=\"text-align: justify;\">3) <em>The ports of the ECCO2 where you connected the temperature sensors, will become red.<\/em> This means that the temperature sensors have to be calibrated. When the temperature sensors are not calibrated, ECCO2 LED light is flashing.<\/p>\n<p style=\"text-align: justify;\">4) <em>In the EAGLE Manager, please click the ADVANCED SETTINGS button<\/em>, this will open a new window. In the top right part of the new window, you will see the CALIBRATE button.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3175\" src=\"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-3.jpg\" alt=\"\" width=\"1000\" height=\"615\" srcset=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-3.jpg 1000w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-3-300x185.jpg 300w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-3-768x472.jpg 768w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-3-50x31.jpg 50w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-3-60x37.jpg 60w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-3-100x62.jpg 100w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<p style=\"text-align: justify;\">5) <em>Click on the CALIBRATE button<\/em> and you will see a red icon that will appear during calibration. When the calibration is complete you will see a \u201cCalibration OK\u201d notification, click OK to confirm and then click OK in the ADVANCED SETTINGS window to close.<\/p>\n<p style=\"text-align: justify;\">6) <em>The port (you connected both the dew heater and the temperature sensor) will become orange<\/em> and this means ECCO2 is automatically controlling the dew power based on the dew point that will be displayed on the EAGLE Manager interface. From this moment ECCO2 takes control of the dew heater power based on the dew point and you can\u2019t manually control power of the dew heater port in the EAGLE until you disconnect the temperature probe from the ECCO2.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3177\" src=\"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-4.jpg\" alt=\"\" width=\"1000\" height=\"600\" srcset=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-4.jpg 1000w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-4-300x180.jpg 300w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-4-768x461.jpg 768w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-4-50x30.jpg 50w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-4-60x36.jpg 60w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-4-100x60.jpg 100w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<p style=\"text-align: justify;\">7) <em>Insert the temperature probe head<\/em> between the dew heater you want to automatically control with the ECCO2 and the telescope optical tube.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3179\" src=\"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-5.jpg\" alt=\"\" width=\"1000\" height=\"600\" srcset=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-5.jpg 1000w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-5-300x180.jpg 300w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-5-768x461.jpg 768w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-5-50x30.jpg 50w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-5-60x36.jpg 60w, https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2021\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-5-100x60.jpg 100w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<p style=\"text-align: justify;\">8) <em>Temperature readings in the ECCO2 are displayed in Celsius (\u00b0C).<\/em> If you want to see temperatures in Fahrenheit (\u00b0F), please go to ADVANCED SETTINGS and select \u201c\u00b0F\u201d in Temperature option.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ECCO2 is designed to work with the EAGLE (compatible with EAGLE4, EAGLE LE, EAGLE3 and EAGLE2 &#8211; in order to work with EAGLE2\u00a0it requires update of OS and EAGLE Manager to v3) and, in order to automatically control dew heater power it doesn&#8217;t need any external software. In order to&#8230;<\/p>\n","protected":false},"author":2,"featured_media":3183,"template":"","format":"standard","meta":{"footnotes":""},"ht-kb-category":[68],"ht-kb-tag":[],"class_list":["post-3184","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-ecco-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>First use: use ECCO2 with EAGLE Manager - PrimaLuceLab<\/title>\n<meta name=\"description\" content=\"In this article we see how to use ECCO2 with EAGLE Manager in order to automatically control power of dew heaters.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"First use: use ECCO2 with EAGLE Manager - PrimaLuceLab\" \/>\n<meta property=\"og:description\" content=\"In this article we see how to use ECCO2 with EAGLE Manager in order to automatically control power of dew heaters.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/\" \/>\n<meta property=\"og:site_name\" content=\"PrimaLuceLab\" \/>\n<meta property=\"article:modified_time\" content=\"2022-01-31T13:01:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"260\" \/>\n\t<meta property=\"og:image:height\" content=\"260\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.primalucelab.com\/blog\/#organization\",\"name\":\"PrimaluceLab\",\"url\":\"https:\/\/www.primalucelab.com\/blog\/\",\"sameAs\":[],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.primalucelab.com\/blog\/#logo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/03\/logo.png\",\"contentUrl\":\"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/03\/logo.png\",\"width\":300,\"height\":83,\"caption\":\"PrimaluceLab\"},\"image\":{\"@id\":\"https:\/\/www.primalucelab.com\/blog\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.primalucelab.com\/blog\/#website\",\"url\":\"https:\/\/www.primalucelab.com\/blog\/\",\"name\":\"PrimaLuceLab\",\"description\":\"Aim high\",\"publisher\":{\"@id\":\"https:\/\/www.primalucelab.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.primalucelab.com\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg\",\"contentUrl\":\"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg\",\"width\":260,\"height\":260,\"caption\":\"First use: use ECCO2 with EAGLE Manager\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#webpage\",\"url\":\"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/\",\"name\":\"First use: use ECCO2 with EAGLE Manager - PrimaLuceLab\",\"isPartOf\":{\"@id\":\"https:\/\/www.primalucelab.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#primaryimage\"},\"datePublished\":\"2020-09-17T15:29:03+00:00\",\"dateModified\":\"2022-01-31T13:01:38+00:00\",\"description\":\"In this article we see how to use ECCO2 with EAGLE Manager in order to automatically control power of dew heaters.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.primalucelab.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\/\/www.primalucelab.com\/blog\/support\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"First use: use ECCO2 with EAGLE Manager\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"First use: use ECCO2 with EAGLE Manager - PrimaLuceLab","description":"In this article we see how to use ECCO2 with EAGLE Manager in order to automatically control power of dew heaters.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/","og_locale":"en_US","og_type":"article","og_title":"First use: use ECCO2 with EAGLE Manager - PrimaLuceLab","og_description":"In this article we see how to use ECCO2 with EAGLE Manager in order to automatically control power of dew heaters.","og_url":"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/","og_site_name":"PrimaLuceLab","article_modified_time":"2022-01-31T13:01:38+00:00","og_image":[{"width":260,"height":260,"url":"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg","path":"\/home\/customer\/www\/primalucelab.com\/public_html\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg","size":"full","id":3183,"alt":"First use: use ECCO2 with EAGLE Manager","pixels":67600,"type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/www.primalucelab.com\/blog\/#organization","name":"PrimaluceLab","url":"https:\/\/www.primalucelab.com\/blog\/","sameAs":[],"logo":{"@type":"ImageObject","@id":"https:\/\/www.primalucelab.com\/blog\/#logo","inLanguage":"en-US","url":"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/03\/logo.png","contentUrl":"https:\/\/www.primalucelab.it\/blog\/wp-content\/uploads\/2021\/03\/logo.png","width":300,"height":83,"caption":"PrimaluceLab"},"image":{"@id":"https:\/\/www.primalucelab.com\/blog\/#logo"}},{"@type":"WebSite","@id":"https:\/\/www.primalucelab.com\/blog\/#website","url":"https:\/\/www.primalucelab.com\/blog\/","name":"PrimaLuceLab","description":"Aim high","publisher":{"@id":"https:\/\/www.primalucelab.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.primalucelab.com\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"ImageObject","@id":"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#primaryimage","inLanguage":"en-US","url":"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg","contentUrl":"https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg","width":260,"height":260,"caption":"First use: use ECCO2 with EAGLE Manager"},{"@type":"WebPage","@id":"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#webpage","url":"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/","name":"First use: use ECCO2 with EAGLE Manager - PrimaLuceLab","isPartOf":{"@id":"https:\/\/www.primalucelab.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#primaryimage"},"datePublished":"2020-09-17T15:29:03+00:00","dateModified":"2022-01-31T13:01:38+00:00","description":"In this article we see how to use ECCO2 with EAGLE Manager in order to automatically control power of dew heaters.","breadcrumb":{"@id":"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.primalucelab.com\/blog\/support\/first-use-use-ecco2-eagle-manager-primo-utilizzo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.primalucelab.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/www.primalucelab.com\/blog\/support\/"},{"@type":"ListItem","position":3,"name":"First use: use ECCO2 with EAGLE Manager"}]}]}},"uagb_featured_image_src":{"full":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"thumbnail":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza-150x150.jpg",150,150,true],"medium":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"medium_large":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"large":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"ht-kb-thumb":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza-50x50.jpg",50,50,true],"1536x1536":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"2048x2048":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"ultp_layout_landscape_large":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"ultp_layout_landscape":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"ultp_layout_portrait":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"ultp_layout_square":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza.jpg",260,260,false],"post-thumbnail":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza-60x60.jpg",60,60,true],"hkb-thumb":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza-100x100.jpg",100,100,true],"crp_thumbnail":["https:\/\/www.primalucelab.com\/blog\/wp-content\/uploads\/2020\/09\/First-use-use-ECCO2-with-EAGLE-Manager-article-evidenza-150x150.jpg",150,150,true]},"uagb_author_info":{"display_name":"Filippo Bradaschia","author_link":"https:\/\/www.primalucelab.com\/blog\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"ECCO2 is designed to work with the EAGLE (compatible with EAGLE4, EAGLE LE, EAGLE3 and EAGLE2 &#8211; in order to work with EAGLE2\u00a0it requires update of OS and EAGLE Manager to v3) and, in order to automatically control dew heater power it doesn&#8217;t need any external software. In order to...","_links":{"self":[{"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb\/3184","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"version-history":[{"count":3,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb\/3184\/revisions"}],"predecessor-version":[{"id":3460,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb\/3184\/revisions\/3460"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/media\/3183"}],"wp:attachment":[{"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/media?parent=3184"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb-category?post=3184"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/www.primalucelab.com\/blog\/wp-json\/wp\/v2\/ht-kb-tag?post=3184"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}